TOCPREVNEXTINDEX

Lund Performance Solutions


Program Messages

Message
Category
Description
Cannot add entries to a string!
Template Notification Message
Chart data character strings (character data) cannot have other items added to them.
Cannot add string entries in a calculation!
Template Notification Message
Chart data character strings cannot be used in mathematical calculations.
Cannot add string entries to the divisor!
Template Notification Message
Chart data character strings cannot be used in mathematical calculations.
Chart entry full! Only 5 items allowed.
Template Notification Message
Performance Gallery Gold allows up to five entries in either the numerator or the divisor fields of a chart data entry.
Critical error in the current entry’s structure!
Template Memory Error
An invalid memory error was encountered that had no other error message assigned to it.
Error - file save should not be executed!
File Save Error
This message should not be encountered as data files in Performance Gallery Gold can only be loaded.
Error defining groups! Groups defined out of order.
Data File Load Error
The data description (header) area of the data file contains blocks of information separated by section headers and delimited by end statements. This message occurs when a statement is either incorrect or encountered out of order. The header section is either corrupt or it did not convert correctly when the file converter was used.
Error defining instances!
Data File Load Error
The data description (header) area of the data file contains blocks of information separated by section headers and delimited by end statements. This message occurs when a statement is either incorrect or encountered out of order. The header section is either corrupt or it did not convert correctly when the file converter was used.
Error in conversion - attempt failed!
File Conversion Error
An unexpected error occurred that could not be categorized. The conversion will abort and the file will not be loaded.
Error loading itemlist - file not present or corrupt!
File Conversion Error
The itemlist file for the selected data file could not be found in the Performance Gallery Gold directory. This file is required for the conversion to succeed.
Error loading template definition file!
File I/O Error
An unexpected error occurred that could not be categorized. The template load will abort.
Error loading the default desktop!
File Load Error
An error occurred while loading the desktop file that cannot be attributed to the operating system and has no other error-specific message. This message is usually encountered with corrupted desktop files or ones that have been transferred between machines using the ftp protocol set to ASCII and not binary code.
Error loading the selected desktop!
File Not Found
The desktop file that was specified does not exist.
Error writing export file to disk!
File I/O Error
An unexpected error occurred that could not be categorized. The export will abort and the file will not be saved.
Error: File Save attempted on a read only file!
File I/O Error
The converter was called on a file save rather than a file load basis. This error should not occur as the converter is called via the data file open command.
File is not a Performance Gallery data file!
Data File Load Error
The identification information in the file that was specified does not match the Performance Gallery Gold series format.
File rename after conversion failed!
Post Conversion Error
The converted file is initially stored with a .pf2 extension and when the conversion is complete, the original file is renamed with a .pfb extension and the converted file is renamed with a .pfg extension. If a .pfb file with the same name already exists in the target directory, or if rename rights are not available on the original file (Windows NT/2000 only), the rename attempt will fail.
File rename after template save failed!
Post Save File Error
The template file is initially stored with a temporary extension. When the operation is complete, the original file is moved out of the way, the new file is put in its place, and the original file is deleted. If rename rights are not available on the original file (Windows NT/2000 only), the rename attempt will fail.
Invalid extension! Unable to export file.
File I/O Error
In the file type pull-down menu for the export graph, there are several available file formats. If the format that is returned by the file Save dialog is not one of the formats supported by Performance Gallery Gold, this error will occur. This error should not be encountered.
Invalid file type. Unable to load desktop file!
Desktop Load Error
The file that was specified is either corrupt or not a Performance Gallery Gold desktop file.
Invalid height or width entry!
Graph Export Error
This error message is displayed when an invalid graph size is entered from the Export dialog box. This error should not occur, because the Export dialog accepts only valid entries regarding graph export size.
Invalid new template name!
Template Save Error
This message is usually encountered when the template name has been left blank or when invalid characters (such as unprintable characters, the "\" character, or other command characters) are included in the template name.
Invalid section definition in the data file!
Data File Load Error
The data description (header) area of the data file contains blocks of information separated by section headers and delimited by end statements. If a statement is encountered out of order or is incorrect, these messages occur. The header section is either corrupt or did not convert correctly when the file converter was used.
Master data table memory allocation failed! Out of memory. Try extracting less data in SOSLOGX or increasing your page file size.
File Load Aborted
There was not enough memory to create the master data table that contains all of the file information. Either more memory (RAM or page file) must be added, or less data must be loaded.
Master data table memory allocation failed! Out of memory. Try increasing your page file size or loading fewer data files.
File Load Aborted
There was not enough memory to create the master data table that contains all of the file information. Either more memory (RAM or page file) must be added or less data must be loaded.
No Type 5 records present!
File Load Failed
The Type 5 records are required by Performance Gallery Gold so the data can be properly indexed and interpreted.
Not all charts could be found!
Desktop Load Error
The desktop contains a list of charts that are based on a template. User-defined templates are stored in a file named tmplates.usr. This file is unique to the machine that it is created on and it is not stored in the desktop. If the desktop is moved between machines or installations of Performance Gallery Gold, the user templates may not be present and Performance Gallery Gold will not be able to load all of the charts.
Only files from the same system may be concurrently loaded!
File Load Aborted
When the multiple file load feature is used, only files from the same host machine can be loaded together. If the Add to Current Data check box in the file Open dialog box is checked and files from different machines are selected to be loaded together, this message will occur.
Only one individual’All’ type allowed per entry!
Template Notification Message
Performance Gallery Gold restricts the number of "All" groups displayed individually to one per entry.
Process information present but not loaded! Process ID field not present.
File Load Warning
In order for process information to be loaded, it must have a unique identifier. The identifier that Performance Gallery Gold uses is a combination of the process name and process ID. Both fields must be present for the process data to be loaded.
Source is not a perfgal D.01 data file!
File Conversion Error
The identification information in the file that was specified does not match the Performance Gallery D.01 series format.
Template file version higher than expected!
File I/O Error
The template file that was loaded contains a version number that is higher than the current version is allowed to load. This generally means that a version of Performance Gallery Gold that is newer than the one reporting this error message created the template file.
The assigned alias already exists! Unable to update the alias entry.
Alias Manager error
The alias entered into the System Alias Manager dialog box has been used before. Assign a new name to the system.
The demo code has expired on this program!
Security Check Failed
Demonstration license codes for Performance Gallery Gold operate for a period up to 99 days. After this period has passed, a new code is required.
The file contains data that is too recent to convert! The license does not allow converting that is this recent.
File Conversion Aborted
This message occurs only on systems that have the licensed version of Performance Gallery Gold. This is due to the fact that the converter will only convert data files containing data that is older than 90 days after the license issue date.
The license code is not present or valid!
Security Check Failed
The license code that was entered was incorrect. The most common cause of this message is that the company name, which is encoded in the license, was entered differently from the one displayed on the paper or message containing the code. Both the company name and the license code must match exactly with those received.
Unable to add new chart element definition!
Template Memory Error
Not enough memory was available to store the information to the template.
Unable to add new chart variable!
Template Memory Error
Not enough memory was available to store the information to the template.
Unable to add new template object!
Memory Error
Not enough memory was available to add a new template in the template list.
Unable to add sample data!
Memory Error
Not enough memory was available to load the data sample into memory.
Unable to allocate new group!
Data File Memory Error
The memory that Performance Gallery Gold requested is not available or the PC is out of memory.
Unable to allocate new instance!
Data File Memory Error
The memory that Performance Gallery Gold requested is not available or the PC is out of memory.
Unable to allocate static information!
Data File Memory Error
The memory that Performance Gallery Gold requested is not available or the PC is out of memory.
Unable to allocate version information!
Data File Memory Error
Not enough memory was available to store the information to the data table.
 
The memory that Performance Gallery Gold requested is not available or the PC is out of memory.
Unable to assign alias!
Data File Memory Error
The memory that Performance Gallery Gold requested is not available or the PC is out of memory.
Unable to assign sub group!
Data File Memory Error
The memory that Performance Gallery Gold requested is not available or the PC is out of memory.
Unable to change chart name - duplicate found!
Template Modify Error
Template names must be unique.
Unable to change chart name - name is preset!
Template Modify Error
The chart templates that are included with Performance Gallery Gold cannot be modified and then saved with the same name. Modified templates must be saved under a different name.
 
A chart already exists with the same name.
Unable to find group matching with element data!
Master Data Error
A memory error occurred when searching through the list of data descriptors. The master index to the data has been corrupted or encountered a memory error.
Unable to initialize the template dialog object! Internet Explorer 3.x or higher may not be present. The application must exit.
Property Sheet Initialization
Microsoft Internet Explorer 3.x or higher includes an updated comctl32.dll file that is required by many programs, including Performance Gallery Gold. If the updated file is not present, tabbed dialog boxes will not be available and will cause the Performance Gallery Gold program to exit.
Unable to load template information!
Template Object Error
The template was not found in memory or was corrupted and could not be retrieved.
Unable to locate discovery records!
File Load Failed
Discovery records were not enabled in the data file. These are required to describe the data so Performance Gallery Gold can correctly index the information.
Unable to open new graph frame window! The application must exit.
Property Sheet Initialization
There was not enough memory available to create the primary display for Performance Gallery Gold. This message is rarely encountered, and it typically occurs on systems with an upgrade edition of Windows 95. The two common causes are that Windows has not been configured correctly or the system did not have a memory optimization before the installation of Windows.
Unable to read data line.
File Load Error
An error occurred while attempting to read a line of data. The line is either too long for Performance Gallery Gold to read, or the data contains unexpected characters due to a newer file format or file corruption.
Unable to read sample data/time stamp!
Data Error/Data File Load Error/File Conversion Error
At least one block of data contains a time value that is not valid.
Unable to save desktop file!
Desktop Save Error
An error occurred while saving the desktop file that cannot be attributed to the operating system and has no other error-specific message.
Unable to update template items!
Template Data Error
An invalid memory error occurred when attempted to manipulate the memory assigned to a template.
Unexpected END statement in the data file!
Data File Load Error
The data description (header) area of the data file contains blocks of information separated by section headers and delimited by end statements. If a statement is encountered out of order or is incorrect, these messages occur. The header section is either corrupt or did not convert correctly if the file converter was used.
Unexpected section in data file! End statement expected.
Data File Load Error
The data description (header) area of the data file contains blocks of information separated by section headers and delimited by end statements. If a statement is encountered out of order or is incorrect, these messages occur. The header section is either corrupt or did not convert correctly if the file converter was used.
Could not connect to pwscomm.dll
Continuous Update
The pwscomm.dll file provides PGG with the ability to talk to the remote systems. If it is not present, no connection attempts will succeed.
Could not parse remote system time data
Continuous Update
The data provided by the remote system must be broken down into its individual items. This is done by the Microsoft XML Parser. This message indicates an error in the parsing that may be due to data corruption or a problem with the XML parser.
Unable to connect to remote system.
 
Continuous Update
The remote system was present but did not accept the attempt to retrieve data. The remote system may not have the data providing service (PWS) installed or configured correctly. Additionally, there may be a networking problem between the machine running PGG and the remote system that is preventing this connection.